Technical reference
For developers and for troubleshooting unusual loggers.
CAT commands handled#
EasyConnect answers as a Kenwood TS-480 (ID020;). Commands end with ;.
| Command | Read reply | Set |
|---|---|---|
ID; | ID020; | — |
PS; | PS1; | ignored |
AI; | AIn; | AIn; turns on pushing IF; when the state changes (per client) |
FA; FB; | 11-digit Hz | sets the VFO |
FR; FT; | 0 / 1 | FR sets the RX and TX VFO (cancels split); FT sets the TX VFO |
MD; | mode code | sets the mode |
IF; | 38-character TS-480 status | — |
TX; RX; | — | PTT on / off |
RT; XT; RC; RU; RD; | RIT / XIT state | RIT / XIT on/off, clear, step |
KY; / KY text; | KY0; | CW text (sent to the radio's keyer where supported) |
AG0; | AG0nnn; AF gain | stored |
FW; | FWnnnn; filter width for the current mode | stored per mode |
SH; SL; | SHnn; / SLnn; high / low cut | stored |
RM; / RMn; | RM10000; meter (SWR 1:1, no ALC) | selects the meter |
VX; | VX0; / VX1; | stored |
RG; | RGnnn; RF gain | stored |
SQ0; SQ1; | SQ0nnn; squelch | stored |
KS; PC; SM; | speed / power / meter | stored |
Anything else is logged as UNKNOWN and answered with ?; (unless Reply ?; to unknown commands is off).
HRD Rig Control requests handled#
The HRD Rig Control server answers as HRD Rig Control with one radio, a TS-480. Both HRD wire formats are accepted: the v5/v6 binary format used by current HRD versions, and the older v4 text lines. Requests may carry a context prefix such as [1]; several requests in one message (TAB-separated) get their replies back the same way.
| Request | What it does |
|---|---|
get id, get version, get context, get radios, get radio | Identify the server and the radio (1:TS-480) |
get frequency, get freqx, get frequencies | Read the frequency (both VFOs for get frequencies) |
set frequency-hz, set frequencies-hz | Tune the radio |
get dropdowns, get dropdown-list, get dropdown-text, get mode | Read the mode (the Mode dropdown) |
set dropdown Mode … | Change the mode |
get split, set split | Read or set split |
get buttons, get button-select, set button-select | The TX, Split, VFO A, VFO B, A / B, RIT and XIT buttons |
get sliders, get smeter-main | Answered with empty or zero values (not emulated) |
Anything else is logged as UNKNOWN.
Default ports#
| Service | Default |
|---|---|
| TS-480 CAT (TCP) | 127.0.0.1:12500 |
| UDP JSON feed | 0.0.0.0:12600 |
| Radio link (WebSocket) | 127.0.0.1:12700 |
| WSJT-X UDP (to loggers) | 127.0.0.1:2237 |
| N1MM Logger+ broadcasts | 127.0.0.1:2333 |
| HRD Rig Control server | 127.0.0.1:7809 |