RemoteTx Manual
remotetx.net

Installing

EasyConnect runs on the computer you operate RemoteTx from, the same one as your browser and your logging software. All installers are also on the Downloads page.

Windows#

Download RTx EasyConnect v2.2.1 for Windows 10/11

  1. Run RTx-EasyConnect-Setup-<version>.exe. It works on any 64-bit Windows 10 or 11 PC and needs nothing else installed.
  2. If Windows SmartScreen warns about the installer, choose More info → Run anyway.
  3. The installer adds RTx EasyConnect to the Start menu and the desktop, and can start it when it finishes.

It installs for the current user, so no administrator rights are needed. Uninstall it from Settings → Apps.

Windows Firewall. The first time EasyConnect runs, Windows may ask about network access. It only needs Private networks, and nothing at all if your loggers run on the same PC. If a logger on another PC needs to reach it (HRD Logbook on a second computer, for example), click Allow through Windows Firewall in the FT8 → loggers card once; Windows asks for administrator approval.

macOS#

There are two packages: RTx-EasyConnect-<version>-mac-arm64.dmg for Apple Silicon (M1 and later) and RTx-EasyConnect-<version>-mac-x64.dmg for Intel Macs.

Download RTx EasyConnect v2.2.1 for Mac (Apple Silicon)

Download RTx EasyConnect v2.2.1 for Mac (Intel)

  1. Open the .dmg and drag RTx EasyConnect to Applications.
  2. The first time, right-click (or Control-click) the app in Applications and choose Open, then Open again. The app isn't notarised by Apple, so a normal double-click is refused the first time.
  3. On macOS 15 or later, if Open isn't offered: System Settings → Privacy & Security, find "RTx EasyConnect" was blocked, and click Open Anyway.
  4. macOS asks once whether EasyConnect may accept incoming connections and find devices on the local network. Allow both. They're needed for loggers on other computers.

First start#

With Start server when the app opens ticked (the default), EasyConnect starts listening straight away:

ServiceDefault addressOn by default
TS-480 CAT server127.0.0.1:12500Yes
Radio link for RemoteTxws://127.0.0.1:12700Yes
FT8 → loggers (WSJT-X UDP)127.0.0.1:2237Yes
N1MM Logger+ broadcasts127.0.0.1:2333No
HRD Rig Control server127.0.0.1:7809No
UDP JSON feed0.0.0.0:12600No
CAT on COM ports—No

The pills at the top of the window show what's running. Then link the radio and connect your logger.

© RemoteTx® · remotetx.net · Manual built 2026 · Updated 2026-11-19